{"product_id":"flexible-rubber-magnetic-leak-patch-213mm-x-206mm-x-13-5mm","title":"Magnetic Leak Patch Kit - 213mm x 206mm x 13.5mm | Flexible PU","description":"\u003ch2\u003ePU Magnetic Leak Patch – 213mm x 206mm x 13.5mm\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003ePU Magnetic Leak Patch – 213mm x 206mm x 13.5mm\u003c\/strong\u003e is a permanent magnetic leak sealing device designed for rapid, temporary containment on steel pipelines, tanks, containers and equipment housings. High-performance permanent magnets embedded in a polyurethane (PU) sealing pad provide magnetic adhesion, holding the patch against the steel surface to help control leakage.\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0398\/9844\/8037\/files\/Magnetic-Leak-Patch-English.pdf?v=1789966082\" title=\"Magnetic Leak Patch User Guide\"\u003eUser guide can be found here.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for industrial emergency response, this magnetic leak patch can be deployed by one person without welding or drilling. It supports leak containment in oil and gas, petrochemical, chemical processing and marine applications, subject to the fluid compatibility, surface condition and operating limits of the installation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e213mm x 206mm x 13.5mm dimensions:\u003c\/strong\u003e Flexible PU sealing pad with an embedded permanent magnetic assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFocused magnetic adhesion:\u003c\/strong\u003e Concentrates the magnetic field on the working surface to provide attachment and sealing pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid deployment:\u003c\/strong\u003e Designed for single-person installation to help reduce leakage and improve emergency response efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNo welding or drilling required:\u003c\/strong\u003e Attaches magnetically without hot-work installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReusable leak patch:\u003c\/strong\u003e The PU pad resists ageing, water and oil and allows repeated installation, subject to inspection and condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded PTFE sealing film:\u003c\/strong\u003e Provides a barrier for compatible chemical media; intended for single use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtective storage bag:\u003c\/strong\u003e Designed to shield the magnetic field and protect the patch during storage and transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis magnetic leak sealing patch is intended for temporary emergency containment on suitable carbon steel and other magnetically receptive steel structures, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial pipelines and petrochemical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage and transport tanks containing compatible liquids or chemicals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteel containers and equipment housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeak points and openings in carbon steel chemical handling equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall breach areas on ships during initial leak containment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine oil containment applications where the patch serves as an anchoring point for boom systems, subject to application assessment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePermanent magnetic leak sealing patch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e213mm x 206mm x 13.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing pad material\u003c\/td\u003e\n\u003ctd\u003ePolyurethane (PU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic assembly\u003c\/td\u003e\n\u003ctd\u003eEmbedded high-performance permanent magnets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttachment surface\u003c\/td\u003e\n\u003ctd\u003eSuitable magnetically receptive steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding force per magnetic module\u003c\/td\u003e\n\u003ctd\u003e≥20 kgf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal holding force of complete magnetic modules\u003c\/td\u003e\n\u003ctd\u003e≥820 kgf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure per unit area\u003c\/td\u003e\n\u003ctd\u003eApproximately 18,644 kgf\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated adhesion pressure\u003c\/td\u003e\n\u003ctd\u003eApproximately 182.7 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplier-stated minimum safe back pressure\u003c\/td\u003e\n\u003ctd\u003e≥1.72 bar (172 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended operating temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePU media compatibility\u003c\/td\u003e\n\u003ctd\u003eVarious waters, oils, gases and chemical fluids at ambient temperature, subject to compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStated PU media pH range\u003c\/td\u003e\n\u003ctd\u003epH 5–9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePTFE sealing film\u003c\/td\u003e\n\u003ctd\u003eIncluded; single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatch reuse\u003c\/td\u003e\n\u003ctd\u003eSubject to inspection, condition and manufacturer instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePerformance note:\u003c\/strong\u003e Holding force and pressure figures are supplier-stated specifications. Total magnetic holding force is not a lifting capacity or a guarantee of sealing performance for every installation. Confirm suitability for the actual leak, steel surface, medium and operating pressure before use.\u003c\/p\u003e\n\u003ch3\u003eFluid Compatibility and PTFE Sealing Film\u003c\/h3\u003e\n\u003cp\u003eThe PU sealing pad is suitable for various types of water, oils, gases and chemical fluids at ambient temperature, including compatible media within a \u003cstrong\u003epH range of 5–9\u003c\/strong\u003e. Chemical suitability must be checked for the specific substance and operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe included \u003cstrong\u003ePTFE sealing film\u003c\/strong\u003e offers resistance to many common industrial acids and alkalis used in electroplating, chemical processing and pharmaceutical applications. The supplier recommends using the film when the medium’s pH or corrosiveness is unknown; compatibility must still be confirmed before deployment.\u003c\/p\u003e\n\u003cp\u003eThe supplied compatibility information identifies fluorine (F₂), chlorine trifluoride (ClF₃) and oxygen difluoride (OF₂) as exceptions to PTFE resistance. The film does not extend the complete patch’s recommended operating temperature range.\u003c\/p\u003e\n\u003ch3\u003eOperating Limits and Safety\u003c\/h3\u003e\n\u003cp\u003eUse within the recommended \u003cstrong\u003e−40°C to +80°C\u003c\/strong\u003e operating range. Exposure above 100°C for more than one hour may reduce magnetic performance. A heat-exposed patch should be assessed before further use.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003etemporary emergency leak containment\u003c\/strong\u003e. Follow the instruction manual and site emergency procedures, and arrange appropriate inspection and permanent repair.\u003c\/p\u003e\n\u003cp\u003eAlthough installation requires no welding or drilling, this does not establish certification for use in explosive atmospheres. Suitability for hazardous areas and hazardous media must be verified before use.\u003c\/p\u003e\n\u003ch3\u003eWhat’s Included?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 × PU Magnetic Leak Patch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × single-use PTFE sealing film.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × protective magnetic shielding storage bag.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × instruction manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat surfaces can the magnetic leak patch attach to?\u003c\/strong\u003e\u003cbr\u003eIt requires a suitable magnetically receptive steel surface. Check the material, surface condition and fit around the leak before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the leak patch be reused?\u003c\/strong\u003e\u003cbr\u003eThe patch is designed for repeated installation, provided it remains serviceable and is inspected according to the manufacturer’s instructions. The PTFE sealing film is single use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes installation require welding or drilling?\u003c\/strong\u003e\u003cbr\u003eNo. Embedded permanent magnets hold the sealing pad against the steel surface, allowing deployment without welding or drilling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it seal chemical leaks?\u003c\/strong\u003e\u003cbr\u003eIt may be suitable for compatible chemical media. Selection depends on the substance, concentration, temperature, pressure and sealing material. Use of the PTFE film does not remove the need to confirm compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a permanent pipe or tank repair?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed for temporary emergency containment while the leak is assessed and a suitable permanent repair is arranged.\u003c\/p\u003e","brand":"AMF Magnetics","offers":[{"title":"Default Title","offer_id":54604915442030,"sku":"59300","price":1246.96,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0398\/9844\/8037\/files\/59301_2_610e5429-06a3-4414-a2f6-a58e52bc5750.png?v=1789102945","url":"https:\/\/magnet.com.au\/products\/flexible-rubber-magnetic-leak-patch-213mm-x-206mm-x-13-5mm","provider":"AMF Magnetics","version":"1.0","type":"link"}